5×20 & 6×25

Description frg7 frg8 frg9
DIMENSIONS 5X20 5X20 5X20
RATED VOLTAGE 250VAC, 40mA, to 12.5A
125VAC, 416A to 20A
380VAC 250VAC, 50mA, to 3A
125VAC, 4A to 8A
CHARACTERISTICS Super Quick Acting Super Quick Acting Quick Acting
APPLICATIONS Used to protect semiconductors (diodes, thyristors, triacs). Limited overload capability. Used to protect semiconductors (diodes, thyristors, triacs). Limited overload capability. Used for the protection of semiconductors and circuits without in-rush currents. Faults cleared very rapidly.
RATED CURRENT 40mA to 20A 100mA to 4A 100mA to 8A
BREAKING 110KA, 125mA to 12.5A 10KA 1500A
CAPACITY 50KA, 16A to 20A
STANDARDS UL 198G, CSA 22.2 no.59-2
Description frg10 frg11 frg12
DIMENSIONS 5X20 5X20 5X20
RATED VOLTAGE 250VAC 250VAC 250VAC
125VAC, 4A to 8A
CHARACTERISTICS Quick Acting Acting Medium Time Lag
APPLICATIONS Used for the protection of semiconductors and circuits without in-rush currents. Faults cleared very rapidly. Used for the protection of semiconductors and circuits without in-rush currents. Faults cleared very rapidly. Used for the protection of circuits with in-rush or transient current conditions.
RATED CURRENT 1A to 6.3A 80mA to 6.3A 1.25A to 12.5A
BREAKING 1500A Greater of 35A or 10 Times rated Current 10KA
CAPACITY IEC 127-2 Sheet 1 IEC 127-2 Sheet 2
STANDARDS UL198G, CSA 22.2 no.59-2
Description frg13 frg14 frg15
DIMENSIONS 5X20 5X20 5X20
RATED VOLTAGE 380VAC 250VAC 250VAC
CHARACTERISTICS Medium Time Lag Time Lag Time Lag
APPLICATIONS Used for the protection of circuits with in-rush or transient conditions. Used for the protection of circuits with in-rush or transient conditions. Used for the protection of circuits with in-rush or transient conditions.
RATED CURRENT 100mA to 3.15A 1A to 6.3A 63mA to 6.3A
BREAKING 10KA 1500A Greater of 35A or 10 Times Rated Current
CAPACITY IEC 127-2 Sheet 5 IEC 127-2 Sheet 3
STANDARDS
Description frg16 frg17
DIMENSIONS 5X20 6×25
RATED VOLTAGE 250VAC, 80mA to 3A 125 VAC, 4A to 8A 250 VAC, 100mA to A 125 VAC, 2.5 to 2A
CHARACTERISTICS Slow Blow Time Lag
APPLICATIONS Used for the protection of circuits with high in-rush or starting conditions. Used for instrument, electronic and small appliances, and general circuit protection.
RATED CURRENT 80mA to 8A 100mA to 7A
BREAKING 200A, 80mA to 3A 10KA, 4A to 8A 10KA, 0.75A or Less 100A, 0.75A to 2A
CAPACITY UL 198G, CSA 22.2 no 59.2 UL 198G, CSA 22.2
STANDARDS